SATs Solar Plant (3900 kW AC / 4640 kWp DC)
LIVE | Next refresh in 45s | | Last updated: —

Technical SCADA Dashboard

Real-time telemetry • Sanand GIDC Phase II, Ahmedabad • 22.9868° N, 72.3787° E
PLANT OVERVIEW Sanand GIDC Solar Plant (Device Config: 16)
📍 Sanand GIDC Phase II, Ahmedabad | 🌅 06:47 AM – 🌇 06:00 PM IST
Total Devices: 16 Online: 14 Offline: 0
Inverters: 13 / 13 Online
MFM: 2 / 2 Online
WMS: 1 / 1 Online
View Details
Production vs Yesterday Loading comparison…
● --
-- kWh today
--
Yesterday same time: -- kWh · yesterday full day: -- kWh
vs 7-day avg--
Projected today--
Weather-adjusted--
Peak power (so far)--
Per-inverter movers
InverterTodayYesterdayChange
Specific Yield
1.45 kWh/kWp
Basis: Summed Inverter AC / 4,640 kWp DC
Plant CUF (24-Hour)
7.2 %
Basis: E_AC / (3,900 kW × 24 h)
Performance Ratio (PR)
59.03 %
Basis: GTI POA Insolation (5.94 kWh/m²)
Plant Efficiency
N/A
Preserved N/A (Requires engineering definition)
Inverter Total Active Power
3200.68 kW
13 Inverters Operating Sum
Inverter Today Generation
6743.10 kWh
Cumulative Today Yield (13 Inverters)
Outgoing Meter Export Today
0.00 kWh
Grid Substation Export (Active: 0.0 kW)
Target Energy Achievement
36.4 %
Target: 18500 kWh
87.4 / 100

Plant Performance Health Score

OPTIMAL HEALTH

Overall plant health score evaluated at 87.4 / 100 based on 100% inverter fleet availability (13/13 Online), strong grid synchronization, and 80.3% Performance Ratio.

• Inverter Availability: 100% (13/13) • Performance Ratio: 80.3% • Grid Power Factor: 0.999 • Health Grade: Tier-1 Operational
Health Score Scale
0 – 49: Critical 🔴
50 – 74: Sub-Optimal 🟡
75 – 100: Optimal 🟢 (87.4)

Solar Electricity Commercial Revenue (Tariff Multiplier)

Real-time financial yield computation: Units Generated (kWh) × Rate per Unit
₹
Today's Inverter Revenue Solar Yield
₹ 35,763.90
6743.10 kWh generated today @ ₹3.00/unit
Grid Substation Export Revenue Discom Feed-in
₹ 35,334.72
0.00 kWh export through Outgoing MFM
Lifetime Plant Commercial Value Cumulative
₹ 47,02,638.00
1894320 kWh cumulative solar generation

Meteorological Station (WMS-01)

Kipp & Zonen Calibrated Sensors
GHI
779.0
W/m²
GTI
1104.0
W/m²
Ambient Temp
34.3
°C
Module Temp
47.4
°C
Humidity
27.5
%RH
GTI Insolation
2.462
kWh/m²
Wind Speed
—
m/s
Cloud Cover
0.0
%

Environmental Offset

IEC Factors
Avoided CO₂ 5.53 tCO₂
Trees Equivalent 270 trees
Coal Avoided 2.7 tonnes

Real-Time Power & Solar Irradiance Profiles

Dual-Axis: Active Power (kW) vs GTI/GHI (W/m²)

Inverter Cumulative Yield vs Meter Export

Comparison of Generation against Export (Daily / Interval 1 Hour)
⚠️ Date Range is limited to a maximum of 7 DAYS. Please select a shorter range.