Recorded measurements for the selected plant, dates and zone. Every output uses this same dataset.
2026-11-05 to 2026-11-05 / Asia/Kolkata15min resolution41 filtered rows13 configured invertersExport: Data
SATs logo, copyright, report notes and official links are included automatically. Exports include all filtered rows; CSV carries chart values and text attribution.
Data register
Date / time (Asia/Kolkata)
Plant daily yield counter (kWh)
Mean active power (kW)
Inverters reporting yield
Inverters reporting power
2026-11-05 10:15
6743.1
3195.679
13
13
2026-11-05 09:45
5004.3
2983.457
13
13
2026-11-05 09:30
4673.9
2880.12
13
13
2026-11-05 09:15
3953.1
2992.294
13
13
2026-11-05 09:00
3205.9
2889.719
13
13
2026-11-05 08:45
2483.5
2726.722
13
13
2026-11-05 08:30
1803.3
2488.722
13
13
2026-11-05 08:15
1182.6
1786.259
13
13
2026-11-05 08:00
741.2
1205.175
13
13
2026-11-05 07:45
441.7
889.919
13
13
2026-11-05 07:30
221.1
546.028
13
13
2026-11-05 07:15
86.7
263.877
13
13
2026-11-05 07:00
21.8
82.837
13
13
2026-11-05 06:45
2.1
9.834
13
13
2026-11-05 06:30
0.0
0.0
13
13
2026-11-05 06:15
0.0
0.0
1
1
2026-11-05 06:00
0.0
0.0
2
2
2026-11-05 05:45
0.0
0.0
1
1
2026-11-05 05:30
0.0
0.0
1
1
2026-11-05 05:15
0.0
0.0
1
1
2026-11-05 05:00
0.0
0.0
1
1
2026-11-05 04:45
0.0
0.0
1
1
2026-11-05 04:30
0.0
0.0
1
1
2026-11-05 04:15
0.0
0.0
1
1
2026-11-05 04:00
0.0
0.0
1
1
Showing 1-25 of 41 rows. Exports contain all rows.
Daily energy counters are not interval generation. Missing measurements remain unavailable; plant totals can cover only the inverters reporting in that interval. This is an engineering report, not a certified settlement statement.
CRITICAL PLANT ALARM DETECTED
PRIORITY 1
Grid Under-voltage Trip — AC active power dropped to 0.00 kW.
Leave technical observations, inverter maintenance notes, or audit findings. Visible to plant owners, developers, administrators, and third-party viewers.
Create Time-Limited Expiring Share Link
Generate a temporary, time-fenced guest access link for stakeholders, contractors, or auditors. Customize which sensitive metrics are displayed or masked.
Generating secure link...
✓ Valid for 1 Hour from creation
Plant Details, GPS & Gallery
SATs Solar Plant
LIVE TELEMETRY FEED•3,900 kW AC / 4,640 kWp DC•22.9868° N, 72.3787° E
⚡PLANT GENERATION TELEMETRY
FX:
⏱️
--:--:-- IST
23 OCT 2026
SCADA STATION LEVEL 1 • SANAND GIDC SOLAR PV FACILITY
Executive Plant Overview & Master Energy KPIs
DISCOM GRID SYNCHRONIZED • 50.02 Hz📅 DAY WISE
TODAY'S ENERGY GENERATION+1.4% Ahead
18,450.60kWh
INSTANT ACTIVE POWER83.3% Utilization
3,248.50kW
PERFORMANCE RATIO (PR)Surplus +3.4%
78.4%
COMMERCIAL REVENUE TODAYPPA ₹3.00/Unit
₹55,351.80
☀️
Global Irradiance (GHI)
845 W/m²
🌡️
PV Module Surface Temp
48.2 °C
⚡
Feeder Export Voltage
11.04 kV
📟
Inverter Fleet Status
13 / 13 Online 1 Warning
🌱
Carbon Offset Today
15.1 MT CO₂
SOLAR IRRADIATION VS POWER PRODUCTION CURVE
Real-Time Diurnal Bell Curve & Grid Telemetry
POLLING CYCLE: 2.5s • MODBUS LATENCY: 12ms📅 DAY WISE
☀️ Real-Time Solar Diurnal Curve (Actual vs Clear-Sky Model vs AI Forecast)
● Actual Power (kW)--- Clear-Sky Target••• Day-Ahead Forecast
GRID EXPORT ACTIVE POWER
3,248.50kW
83.3% of 3.90 MW Capacity
REACTIVE POWER (Q)
+284.10kVAR
cos φ = 0.996 Lagging
GRID FREQUENCY
50.02Hz
Nominal 50.00 Hz (Band: 49.90 - 50.05)
DC TO AC EFFICIENCY
98.42%
Clipping Loss: 0.00% • THD: 1.8%
STRING & CENTRAL CONVERTER FLEET • 13 UNITS
Inverter Fleet Telemetry & Thermal Health Matrix
12 Optimal1 Attention (INV-08)0 OfflineFleet Total: 3,248.5 kW📅 DAY WISE
INV-01
278.4 kW
DC: 742VAC: 412ATemp: 44.2°CEff: 98.6%
INV-02
279.1 kW
DC: 745VAC: 414ATemp: 44.8°CEff: 98.7%
INV-03
277.8 kW
DC: 740VAC: 411ATemp: 45.1°CEff: 98.5%
INV-04
281.2 kW
DC: 748VAC: 416ATemp: 45.5°CEff: 98.7%
INV-05
276.5 kW
DC: 739VAC: 410ATemp: 43.9°CEff: 98.6%
INV-06
280.0 kW
DC: 746VAC: 415ATemp: 44.7°CEff: 98.6%
INV-07
279.4 kW
DC: 744VAC: 413ATemp: 44.5°CEff: 98.7%
INV-08 [ALARM]
254.2 kW
DC: 731VAC: 385ATemp: 48.4°C ⚠️Eff: 97.8%
ERR-402: Auto-Throttled 92%
INV-09
278.0 kW
DC: 741VAC: 412ATemp: 44.0°CEff: 98.6%
INV-10
281.8 kW
DC: 749VAC: 417ATemp: 45.2°CEff: 98.8%
INV-11
277.1 kW
DC: 740VAC: 411ATemp: 44.3°CEff: 98.6%
INV-12
279.8 kW
DC: 745VAC: 414ATemp: 44.9°CEff: 98.7%
INV-13
280.2 kW
DC: 746VAC: 415ATemp: 44.6°CEff: 98.7%
11 kV STEP-UP SUBSTATION & INTERCONNECTION FEEDER
Multi-Function Meter (MFM) & Grid Power Quality
TRANSFORMER T1: 4.5 MVA • OIL TEMP: 58.4°C📅 DAY WISE
⚡ 3-Phase Line-to-Line Voltages (11 kV Bus)
Phase R-Y11,042 VNormal
Phase Y-B11,038 VNormal
Phase B-R11,045 VNormal
Average Bus Voltage: 11.04 kV (Nominal 11.00 kV • Deviation: +0.36%)
🌊 3-Phase Export Currents
Current I_R184.2 ABalanced
Current I_Y183.9 ABalanced
Current I_B184.5 ABalanced
Current Unbalance: 0.18% (Permissible limit < 3.0%)